Expert Talk

Utilizing corrosion testing for reliable materials selection

Björn Helmersson

Corrosion specialist
Outokumpu

Björn Helmersson explains how corrosion testing can be used to help select the most suitable stainless steel for a specific application.

The outstanding corrosion resistance of stainless steel results from its ability to form a thin, compact and stable surface film, rich in chromium. This film protects the material below the surface, making stainless steel non-reactive in many environments – we say that the material is passive. However, corrosion can occur when the passive film is breached – by chlorides or other aggressive species – or if it is not stable, such as in some acids and bases. To reliably select a material for a given application, we need to know that the material will be compatible with the conditions it will be used in. Corrosion testing plays an important role in ensuring that the selected stainless steel grade will perform well in its working environment.

 

The aims of corrosion testing

As a material supplier, Outokumpu aims to provide its customers with the best tools possible for cost-effective and reliable material selection. To fulfill this goal, large amounts of corrosion data need to be generated and a suitable test method must be used. A good test method for this purpose should be:

  • As simple and fast as possible without sacrificing reliability
  • Suitable for use across a wide range of corrosion media
  • Able to generate results that can be translated to real- life conditions

The method that is most commonly used at Outokumpu is called ISO 18069 and utilizes three test periods to assess the material’s response to its exposure conditions.

 

Uniform corrosion testing with sample activation

In the third test period of ISO 18069, the passive film is deliberately destabilized by touching the sample with a zinc rod. This causes the material to start corroding actively and evaluates the material’s ability to reform the passive film (or repassivate) after being activated. If the corrosion rate is low in this test period, the material is not only able to maintain its passive film – it is also able to reform it after it is dissolved. 

In real service conditions, activation could occur if the conditions are temporarily more aggressive than usual, or if the passive film is mechanically compromised by abrasive conditions. Including this step during corrosion testing provides an extra safety margin in the corrosion data. 

 

Corrosion tables 

Corrosion data can be presented in a variety of ways. The format used most by Outokumpu is the corrosion tables available in our Corrosion Handbook. Figure 1 shows an excerpt from these tables. Corrosion tables are available for a wide range of media, including inorganic and organic acids, alkaline media, foodstuffs, metals and salts. The tables indicate the expected corrosion rate for a specific steel grade in different environments. 

The material performance is rated as 0, 1 or 2. 0 - meaning that the material is compatible with the conditions and has a corrosion rate below 0.1 mm/year. 1 means that the material is expected to corrode at a rate between 0.1 and 1 mm/year, so it may be useable in some applications, but it is not completely resistant. 2 means that the material will corrode heavily at a rate above 1 mm/year.

Isocorrosion diagrams 

Isocorrosion diagrams are based on the same data as the corrosion tables, but presented as a line that represents a corrosion rate of 0.1 mm/year. This gives an easy to grasp overview of the material’s limits in a range of concentrations. At a temperature below the line, the material is expected to perform well, but at higher temperatures it is no longer resistant. 
As an example, if we want to store a sulfuric acid solution of 20 mass-% at 60°C, we could take a look at the isocorrosion diagram in Figure 2. This would show us that Supra 316L/4404 will not be suitable. We will instead have to go for a higher alloyed grade, such as Ultra 904L. 

 

Applicability 

Although a wide range of conditions are available in the Corrosion Handbook, the real world is seldom so simple. Before blindly using these guidelines, we need to consider if there are any other factors that may affect the corrosivity. The tests are performed in pure chemicals at constant conditions. In real operating conditions there may be contaminants, process variations or a different oxygen content. These factors can in some cases be critical to material performance. 

The effect of some contaminants on the corrosivity of sulfuric acid are illustrated in the three isocorrosion diagrams shown in Figure 3. The aggressive chlorides in Figure 3B shift the lines towards lower temperatures compared to the pure conditions in Figure 3A, indicating lower corrosion resistance for the respective grades. 

In Figure 3C the oxidizing contaminant chromic acid has been added to the sulfuric acid. This contaminant has a clear positive effect and shifts the lines towards higher temperatures. However, as the oxidant concentration increases, the positive effect diminishes. 

This shows us that the effect of contaminants on the corrosion resistance is not always clear-cut. Some contaminants make the conditions significantly more aggressive. Others may have a positive effect – but even in those cases, a higher contaminant concentration does not necessarily mean better performance. 

The concentration dependence of the corrosivity should also be considered. The expectation might be that a higher acid concentration causes more aggressive conditions. This is not always true and depends strongly on the type of media. This is illustrated in Figures 4A-C. While the hydrochloric acid follows the expected trend, the sulfuric acid and formic acid are most aggressive in the intermediate concentrations. This effect is also dependent on steel grade. It is clear that higher concentration does not always mean that the media will be more aggressive. 

 

Oxygen content and aeration

Oxygen content is known to be an important parameter in terms of corrosivity. Generally, a better corrosion performance is expected in conditions with low oxygen contents than in aerated conditions. This is, however, not true in all cases. Figure 5 shows isocorrosion diagrams for Ultra 904L in sulfuric acid, with and without deaeration. While it is obvious that oxygen content has an effect on corrosivity, it is less obvious what this effect will be. As such, oxygen content is an important parameter to consider. All data in Outokumpu’s corrosion tables and isocorrosion diagrams are performed in naturally aerated conditions, unless specified otherwise. 

 

The importance of including all types of corrosion 

The corrosion tables and isocorrosion diagrams we have looked at are primarily used for uniform corrosion. The test method used to generate this data is designed to estimate the uniform corrosion rate and may not reliably predict other corrosion types. In most of the conditions presented in these tables and diagrams, uniform corrosion is the main expected corrosion type. 

However, other types of corrosion may occur. In conditions where this is expected, it is indicated in the corrosion tables. For example, contaminants such as chlorides may induce localized attacks like pitting and crevice corrosion. Localized corrosion types follow more complex mechanisms and are more difficult to predict. To deal with these corrosion types another toolbox may be required. 

Conclusions

Laboratory testing can be a useful and efficient tool for assessing the corrosion performance of a material.

  • Corrosion tables and isocorrosion diagrams are good first steps
  • Real conditions are always different – this has to be considered
  • Corrosion rates for uniform corrosion can be predicted utilizing laboratory methods
  • Localized corrosion may occur in some media. This type of corrosion is less predictable

Recommended pages

Ultra
Corrosion resistance

Expert talks

Article

What if beauty lasted for centuries?

Article

What if bridges were built to last?

Article

Home of Rioja wine toasts sustainable stainless steel footbridge

Case Kavika hygienic fixtures

No chance for germs

Article

What if stainless competed in the Olympics of Materials?

Technical article

The stainless steel family – introducing the different categories and grades

Article

Ultra Alloy 825 hits the sweet spot for the oil and gas industry

Case Mine rescue chambers

Stainless saves lives underground

Article

What if cities were built tall and green?